Canberra
19.1 Evaporation from urban water system

Supporting information

a. Evaporation from urban water system

This line item refers to the volume of water that was calculated as loss through evaporation at the sewage treatment plants (STPs) in the Canberra region:  Lower Molonglo Water Quality Control Centre (LMWQCC), Fyshwick, Uriarra, Outward Bound operated by ACTEW Water, and the Queanbeyan STP operated by Queanbeyan City Council (QCC). The total volume reported in the 2013 Account is 3,877 ML.


Evaporation losses at waste water treatment plants
Water authority Sewage treatment plant Evaporation loss
(Volume in ML)
ACTEW Fyshwick 899
LMWQCC 2,704
Uriarra 1
Outward Bound  0
subtotal 3,604
QCC Queanbeyan 273
Total 3,877

b. Wastewater system overview

The following figure shows all the inflows and outflows associated with the wastewater system.

The treated wastewater volume discharged to surface water after treatment was 31,636 ML, approximately 77% of total treated wastewater volume, 41,114 ML.

During the 2012–13 year, approximately 12% of treated wastewater was recycled; the rest was the losses. The following figure shows all the inflows and outflows associated with the wastewater system.

For more detail on a particular flow associated with the recycled water system, refer to the line item notes. Note that volumes annotated with an * indicate flows between sub-components and are not reported in the account. As such, these flows do not have an associated line item number.


Schematic diagram of water inflows and outflows during the 2012–13 year for Canberra's wastewater system. Line item numbers are provided in brackets.
Schematic diagram of water inflows and outflows during the 2012–13 year for Canberra's wastewater system. Line item numbers are provided in brackets.

Quantification approach

ACTEW Water

Data source

Water Data Warehouse.

Provided by

ACTEW Water.

Method

The reported volume of water lost through evaporation is calculated as the difference between the known inflows and outflows to Sewerage treatment plants:  LMWQCC, Fyshwick Wastewater, Uriarra, and Outward Bound.


Calculation of losses at the LMWQCC, Fyshwick, Uriarra and Outward Bound wastewater treatment plants
Component ACTEW STPs
(Volume in ML)
Fyshwick LMWQCC Uriarra Outward Bound  Total
wastewater  inflow   31,777      
Fyshwick returned to sewer   (606)      
wastewater collected  1,559 31,171 11 2 32,743
           
inflow for treatment 1,559 31,777 11 2 33,349
losses (e.g. Dam spills)   0     0
recirculated water added   4,275     4,275
Total volume for treatment 1,559 36,052 11 2 37,624
           
wastewater treated 1,559 36,052 11 2 37,624
discharge to surface water    28,988 10   28,998
discharge to landscape          
recycled water produced  54 4,360   2 4,416
discharge to sewer 606        
Total outflow  660 33,348 10 2 34,020
Losses ( Wastewater treated  -  Total outflow) 899 2,704 1 0 3,604


Assumptions, limitations, caveats and approximations

Nil.

Uncertainty information

The uncertainty estimate was not quantified.

Queanbeyan City Council

Data source

QCC.

Provided by

QCC.

Method

Evaporation was measured from four lagoons, two sludge lagoons, and other smaller open water bodies such as aeration tanks. The moisture content of sludge was not was not included.


Calculation losses at the Queanbeyan sewage treatment plant
QCC: Queanbeyan STP
Component Volume in ML
wastewater collected  2,965
   
inflow for treatment 2,965
recirculated water added 525
Total volume for treatment 3,490
   
wastewater treated 3,490


discharge to surface water  2,638
recycled water produced  579
Total outflow  3,217
Losses ( Wastewater treated  -  Total outflow) 273

Assumptions, limitations, caveats and approximations

Nil.

Uncertainty information

The uncertainty was not quantified.