The total metered volume of treated wastewater discharged to the sea at wastewater treatment plants and water recycling plants managed by Shoalhaven City Council and Sydney Water Corporation during 2009–10 was 395,186 ML (see the following table).
Managing authority | Plant type | Plant | Discharge volume to sea (ML) |
---|---|---|---|
Shoalhaven City Council | Wastewater treatment | Shoalhaven Heads* |
152 |
Sydney Water Corporation | Wastewater treatment | Bellambi |
356 |
Port Kembla |
505 |
||
Warriewood |
5,811 |
||
Shellharbour |
6,056 |
||
Cronulla |
18,865 |
||
Bondi |
44,548 |
||
North Head |
133,570 |
||
Malabar |
171,557 |
||
Water recycling plant | Gerroa |
148 |
|
Bombo |
1,327 |
||
Wollongong |
12,291 |
||
Total |
395,186 |
||
* Discharge occurs via sand dunes to the sea. |
This line item comprises two different data-sets. The method for each data-set is shown below.
NSW Water Supply and Sewerage: ‘Performance monitoring’ Report 2009–10. (Access through the ‘Performance monitoring’ webpage of the NSW Office of Water. The report will be included on the webpage from June 2011.)
Shoalhaven City Council.
Outflow volumes from Shoalhaven Heads Wastewater Treatment Plant were measured using an Elster meter and a Parshall flume with a venturi flow meter.
The volume is based on measured data. Estimated uncertainty based on meter accuracy is +/–5%.
Treated wastewater was discharged to the sea via sand dunes, which act as natural sand-bed filters.
Data managed and maintained in an internal data management system by Sydney Water Corporation’s Operations Division (Systems Assurance).
Sydney Water Corporation.
The number represents the total volume of treated wastewater discharged to the sea, based on flow meter readings from wastewater treatment plants and water recycling plants managed by Sydney Water Corporation.
The flow of wastewater from the plants was measured using flow meters. These measured data are continually monitored and recorded using the Integrated Instrumentation Control Automation and Telemetry System (IICATS). The data is stored within an internal data management system. Adjustments are made to the data (if necessary) to correct any interruptions, errors and so on. Data have been extracted for 2009–10 from the data management system.
The volume is based on measured data. Estimated uncertainty based on meter accuracy is +/–2%.
Nil.